Hood Cleaning and Fire Suppression Inspections

How often kitchen hoods, ducts and fire suppression systems need inspection and cleaning, what the fire marshal checks, and the records and tags to keep.

AssistCall research teamPublished Reviewed by Faruque Amin, VP of Sales and Marketing7 min read

On this page
  1. Three systems, three schedules
  2. Hood and duct cleaning frequency
  3. What a good hood cleaning service includes
  4. Fire suppression system service
  5. Portable extinguishers and staff training
  6. What the fire marshal checks
  7. Example: a wok kitchen tightens its schedule
  8. Daily and weekly staff tasks
  9. Frequently asked questions
  10. References
Food Safety, Health and Licensing: Hood Cleaning and Fire Suppression InspectionsArticle coverFOOD SAFETY, HEALTH AND LICENSINGHood Cleaning and FireSuppression InspectionsAva for RestaurantsInsightsFood Safety, Health and Licensing: Hood Cleaning and Fire Suppression InspectionsArticle coverFOOD SAFETY, HEALTH AND LICENSINGHood Cleaning andFire SuppressionInspectionsAva for Restaurants

Key takeaways

  • Hood, duct and suppression inspection intervals come from your local fire code, which usually adopts NFPA 96 and scales frequency to the type and volume of cooking.
  • OSHA requires portable fire extinguishers to be visually inspected monthly and maintained annually, with records kept[1].
  • The Food Code requires intake and exhaust ducts to be cleaned and filters changed so they do not become a source of contamination[2].
  • Keep service tags current, certificates on file and the suppression pull station clear; those are the first things a fire marshal checks.

Three systems, three schedules

A commercial kitchen's fire protection is really three systems that work together, each with its own inspection routine. The exhaust hood and ducts remove grease-laden vapor and must be kept clean so that grease does not build up and burn. The fixed suppression system over the cooking line discharges a wet chemical agent and shuts off fuel when it detects a fire. Portable extinguishers, including Class K units for cooking oil fires, are the staff's first response.

Kitchen fire protection systems and who looks after each
SystemWho inspects or services itWhere the rules come from
Exhaust hood, filters and ductsCertified hood cleaning contractor; staff clean filtersLocal fire code, usually adopting NFPA 96; health code for cleanliness
Fixed suppression systemLicensed fire protection service companyLocal fire code and the system manufacturer's instructions
Portable extinguishers, including Class KStaff monthly checks; service company annuallyOSHA for workplaces, plus local fire code
Fuel and electrical shutoffs tied to suppressionSuppression service company during each serviceFire code and manufacturer's instructions

Hood and duct cleaning frequency

Most US fire codes adopt NFPA 96, the National Fire Protection Association's standard for ventilation control and fire protection of commercial cooking operations. It sets how often an exhaust system must be inspected for grease build-up according to the type and volume of cooking: most frequently for solid-fuel cooking such as wood or charcoal, then for high-volume operations such as kitchens that cook around the clock, charbroiling or wok cooking, then moderate-volume kitchens, and least often for low-volume operations such as seasonal businesses. When an inspection finds the system contaminated with grease deposits, it must be cleaned.

The exact interval depends on the edition your jurisdiction has adopted and how your fire marshal applies it. Ask the fire marshal's office for the interval that applies to your kitchen, in writing, and give it to your contractor. Then let your own records decide whether you need cleaning more often. A charbroiler line in a busy burger restaurant will need a much tighter schedule than a cafe kitchen that mostly bakes.

The health code has a say too. The FDA Food Code requires intake and exhaust air ducts to be cleaned and filters changed so that they are not a source of contamination by dust, dirt or other materials[2]. Grease dripping from a dirty hood onto food or a prep surface is both a fire risk and a health violation. In New York City, ventilation that fails to prevent excessive build-up of grease, heat, steam, odors, smoke or fumes is scored at 2 to 5 points depending on condition[3].

What a good hood cleaning service includes

  1. Pre-service inspection

    The technician inspects the hood, filters, ducts and fan and photographs grease levels before cleaning, including hard-to-reach duct sections.

  2. Full system cleaning

    Cleaning covers the hood, plenum, filters, all accessible ductwork to the exhaust fan, and the fan itself, not just the visible canopy.

  3. Access panels

    If ducts cannot be reached, the contractor should tell you and recommend access panels. A clean hood over a dirty duct is a common hidden risk.

  4. Fan and hinge check

    The rooftop fan should be cleaned, its belt checked, and a hinge kit fitted if your code requires one for safe cleaning access.

  5. Certificate and label

    The contractor leaves a dated label on the hood and a written report with before and after photos and any deficiencies.

  6. Clean-up

    Waste water and grease go into the contractor's containment, not your floor drains, so they do not overload your grease trap.

Ask for photos of the duct interior and the fan, not just the hood. Those are the parts you never see and the parts most likely to be missed.

Fire suppression system service

The wet chemical suppression system needs regular service by a licensed fire protection company, on the schedule your fire code and the manufacturer set. Ask your fire marshal and your service company for the interval in writing. A typical service includes checking the agent cylinders and pressure, replacing fusible links on the schedule the manufacturer requires, testing the detection line, confirming that the system shuts off gas and electric supply to the cooking equipment, and checking that nozzles are aimed at the appliances they protect.

  • Re-service the system whenever you move, add or replace cooking equipment under the hood. Nozzle coverage is designed for specific appliances in specific positions.
  • Keep the manual pull station visible and unobstructed, and train staff on where it is and when to use it.
  • Never disconnect, bag or cover nozzles, and never hang anything from the detection line.
  • After any discharge, call the service company and do not cook under the hood until the system is recharged and tagged.

Portable extinguishers and staff training

For portable extinguishers, OSHA's workplace rule sets clear minimums. Extinguishers must be visually inspected monthly and must get an annual maintenance check, with the maintenance date recorded and kept for one year after the last entry or the life of the shell, whichever is less[1]. Employers who provide extinguishers for employee use must train staff on general use upon hiring and at least annually after that[1]. For Class B hazards such as flammable liquids, the travel distance to an extinguisher must be 50 feet or less[1].

OSHA minimums for portable fire extinguishers, per year29 CFR 1910.157: monthly visual inspection, annual maintenance, training at hire and at least annually
OSHA minimums for portable fire extinguishers, per yearColumn chart. Visual inspections: 12×; Maintenance checks: 1×; Staff training sessions: 1×.0×5×10×15×Visual inspections: 12×12×Visual inspectionsMaintenance checks: 1×1×Maintenance checksStaff training sessions: 1×1×Staff training sessionsOSHA minimums for portable fire extinguishers, per yearColumn chart. Visual inspections: 12×; Maintenance checks: 1×; Staff training sessions: 1×.0×5×10×15×Visual inspections: 12×12×VisualinspectionsMaintenance checks: 1×1×MaintenancechecksStaff training sessions: 1×1×Stafftrainingsessions

Source: Legal Information Institute (Cornell Law School), 2026[1]

Show the data
TaskMinimum per year
Visual inspections12×
Maintenance checks1×
Staff training sessions1×
  • Keep a Class K extinguisher near the cooking line for oil and grease fires, as your fire code requires, and train staff to use it only after the suppression system has activated or for small fires.
  • Do the monthly visual check on a set day: pin and seal intact, gauge in the green, no damage, tag current, and unobstructed.
  • Teach the basics in every new-hire orientation: pull the station, shut off fuel if safe, never throw water on a grease fire, and get out if the fire is not out quickly.

What the fire marshal checks

  1. A current hood cleaning label and report, with the interval matching the fire marshal's requirement for your type of cooking.
  2. A current suppression system service tag, with no expired or missing tags.
  3. Nozzles positioned over the appliances they protect, with no equipment moved or added since the last service.
  4. Filters in place, the right type, undamaged and not dripping grease.
  5. An unobstructed manual pull station and a working fuel shutoff.
  6. Portable extinguishers, including Class K, in place, charged, tagged and accessible.
  7. No grease build-up on the hood exterior, walls or ceiling around the line.
  8. Clear exits, exit signs lit, and no storage in front of electrical panels.

Keep all of these records in one fire safety binder next to your health inspection binder. When the fire marshal arrives, the person in charge should be able to produce the hood report and suppression tag in under a minute.

Example: a wok kitchen tightens its schedule

Example: a fictional noodle restaurant with four wok burners had its hood cleaned on the same schedule as the cafe that previously occupied the space. The contractor's photos showed heavy grease in the horizontal duct run within weeks of each cleaning. The fire marshal's office confirmed that wok cooking falls in the high-volume category in its adopted standard.

In this example, the owner moved to the shorter interval the fire marshal specified, had access panels added to the horizontal duct, switched staff filter cleaning from weekly to nightly, and had the suppression company verify nozzle coverage for the wok burners, which had been installed after the last service. The next inspection found clean ducts and correct tags.

Daily and weekly staff tasks

  • Nightly: wipe down the hood exterior and empty grease cups or troughs.
  • Nightly or weekly, depending on volume: remove and clean baffle filters in the dish machine or a soak tank, so wash water goes through your grease trap.
  • Weekly: check that filters seat properly with no gaps, and replace damaged ones.
  • Monthly: extinguisher visual check and log; look for loose or missing suppression nozzle caps.
  • Whenever equipment moves: call the suppression company before cooking under the hood.

Grease that comes off the hood has to go somewhere, which links this routine to grease trap maintenance and local rules. Fire inspections are also on your opening and renewal list; see restaurant permits and licenses checklist, and the health code's cleaning expectations in restaurant cleaning schedule template. The FDA Food Code now has a 2026 edition[4], but fire intervals come from your fire code, so confirm them with the fire marshal. For other compliance topics nearby, see menu calorie labeling rules. This article is general information, not legal or fire safety advice.

Frequently asked questions

How often should a restaurant hood be cleaned?

As often as your fire code requires for your type and volume of cooking, which most codes base on NFPA 96, and more often if inspections find grease build-up. Ask your fire marshal for the interval in writing.

How often is a fire suppression system inspected?

On the schedule your fire code and the system manufacturer set, by a licensed fire protection company, and after any equipment change or discharge. Confirm the interval with your fire marshal.

How often do kitchen fire extinguishers need checking?

OSHA requires a monthly visual inspection and an annual maintenance check, with records kept[1].

Does the health inspector check the hood?

Yes, for cleanliness. The Food Code requires ducts and filters to be kept from becoming a source of contamination[2].

References

  1. Legal Information Institute (Cornell Law School) (2026). 29 CFR § 1910.157: Portable fire extinguishers (opens in a new tab) ↑

  2. US Food and Drug Administration (2022). FDA Food Code 2022 (opens in a new tab) ↑