Key takeaways
- EPA's report to Congress found grease from restaurants, homes and industry to be the most common cause, 47%, of reported sewer blockages[1].
- Federal pretreatment rules ban discharges that obstruct sewers, and local utilities set the actual limits; 100 mg/L of oil and grease is the most common numeric limit[1].
- Enforcement is real: after finding 73% of restaurants out of compliance, New York City set a $1,000-a-day fine for grease violations[1].
- Clean on the schedule your utility sets, keep every hauler manifest, and train the kitchen to keep grease out of the drains.
Why utilities care about your grease
Fats, oils and grease, usually shortened to FOG, wash down kitchen drains as hot liquid and turn solid as they cool in the sewer. Over time they narrow pipes, catch debris and cause blockages that back sewage up into streets, basements and, sometimes, the restaurant that caused them. EPA's report to Congress on sewer overflows found that grease from restaurants, homes and industrial sources is the most common cause, at 47%, of reported blockages[1].
That is why grease control is enforced by your sewer utility, not just your health department. The legal basis is EPA's National Pretreatment Program: its regulations prohibit solid or viscous pollutants in amounts that will cause obstruction in the sewer system, and local utilities build their grease programs on that rule[1].
What local FOG rules usually require
Each utility writes its own ordinance, so details vary from city to city. Most programs, though, are built from the same parts, and EPA describes many of them: grease interceptors or traps, best management practices for kitchens, inspections, periodic pumping, penalties and, in some places, monthly surcharges on restaurant sewer bills[1].
- A requirement to install and maintain a grease interceptor or trap of an approved size, often reviewed with your building permit.
- A numeric limit on oil and grease in your wastewater. EPA identified typical local limits of 50 mg/L to 450 mg/L, with 100 mg/L the most commonly reported[1].
- A minimum cleaning frequency, or a rule that you pump when grease and solids reach a set share of the device's capacity.
- Use of a licensed or registered hauler, with a manifest for each pump-out.
- Kitchen best management practices, often with staff training records.
- Inspections, and penalties or surcharges for violations. EPA notes surcharges reportedly ranging from $100 to as high as $700 or more[1].
Source: US Environmental Protection Agency, 2012[1]
Show the data
| Limit | Milligrams per liter |
|---|---|
| Low end of range | 50 mg/L |
| Most commonly reported | 100 mg/L |
| High end of range | 450 mg/L |
Traps, interceptors and what the Food Code says
Restaurants use two main kinds of device. A grease trap, sometimes called a hydromechanical interceptor, is a smaller unit often installed under or near a sink. A gravity grease interceptor is a large tank, usually in the ground outside, that serves the whole kitchen. Which you need is set by your plumbing code and utility, based on your flow and menu.
The FDA Food Code adds one simple rule from the health side: if a grease trap is used, it must be located so that it is easily accessible for cleaning[2]. A trap boxed in under a prep table, or an interceptor lid under a parked car, will not be cleaned as often as it should be. Plan access during design.
Do not connect a dishwasher to a small under-sink trap unless your plumbing code and utility allow it. Hot, soapy dish water can carry grease straight through a small trap.
How often to clean
The right interval depends on the device size, your menu and how well the kitchen keeps grease out of the drains. EPA notes that service frequency depends on how much FOG an establishment produces and on the practices it follows, and that kitchens with good practices often reduce how often their interceptors need maintenance[1]. Your utility's rule is the minimum.
Find the rule
Ask your utility for its minimum cleaning frequency and any percentage-of-capacity rule, in writing.
Measure for a month
Have your hauler or a trained staff member measure grease and solids depth at a set interval, and record it.
Set your schedule
Choose a pumping interval that keeps you well below the utility's capacity limit at your busiest season, not your average week.
Clean small traps in-house only if allowed
Some utilities let staff clean small under-sink traps; many require a licensed hauler for interceptors. Never pour trap contents down another drain.
Inspect baffles and lids
Ask the hauler to check baffles, tees and lids at each service and to note damage on the manifest.
Review annually
Look at a year of manifests and measurements. If grease levels keep running high, fix kitchen habits before adding pump-outs.
Kitchen habits that keep grease out of the drains
- Scrape plates, pots and pans into the trash or compost before washing.
- Dry-wipe greasy pans and sheet trays with a paper towel before they reach the sink.
- Use sink strainers and floor drain screens, and empty them into the trash.
- Collect used fryer oil and pan grease in a covered container for a rendering or recycling service; never pour it down a drain.
- Do not use hot water or chemicals to push grease through the trap; check whether your utility restricts additives such as enzymes before using any.
- Clean exhaust hood filters over a sink only if the wash water goes through the grease trap, or have the hood contractor take the waste.
- Clean up oil spills with absorbent material, not by hosing them into a floor drain.
- Post a simple sign at each sink and train every new dishwasher on day one.
These steps also reduce drain flies and odors, which matter for pest control; see hood cleaning and fire suppression inspections for the other place grease builds up in a kitchen.
Records the utility will ask for
- Your FOG discharge permit or registration, if your utility issues one.
- Hauler manifests for every pump-out: date, volume removed, hauler name and license number, disposal site.
- A maintenance log for any device your staff clean, with dates, depth measurements and initials.
- Receipts from your used cooking oil recycling service.
- Training records for kitchen best management practices.
- Any inspection reports and correspondence with the utility.
Keep at least the period your ordinance requires, and keep copies off site or in the cloud. A missing manifest can turn a passed inspection into a violation.
What a backup costs
Enforcement varies, but it can be expensive. EPA cites New York City, which instituted a $1,000-per-day fine for FOG violations after identifying a 73% non-compliance rate with its grease trap ordinance among restaurants[1]. And a backup inside the restaurant is a health violation as well as a plumbing bill. In New York City's inspection scoring, a food preparation or storage area contaminated by sewage or liquid waste is scored at 10 or 28 points depending on the condition[3], enough on its own to lose an A grade; see restaurant letter grades and posted scores.
Example: from monthly emergencies to a planned schedule
Example: a fictional fried chicken restaurant calls an emergency plumber three times in six months for slow kitchen drains. Its in-ground interceptor is pumped every 90 days, the minimum its utility allows. The hauler's measurements show the interceptor reaching the utility's capacity limit in about six weeks during summer.
In this example, the owner moves to pumping every six weeks from May to September and every ten weeks the rest of the year, adds strainers to every sink, and starts dry-wiping fryer baskets and sheet trays. Used oil moves to a covered recycling container collected weekly. The emergency calls stop, and the next utility inspection finds complete manifests and a trained dish team.
Getting started in a new space
Before signing a lease, ask the landlord and the utility whether the space has an interceptor, its size and condition, and whether your planned menu would require a larger one. Retrofitting an interceptor can be a major construction cost. It belongs on your restaurant permits and licenses checklist from day one, alongside health, building and fire approvals. FDA has issued a 2026 edition of its Food Code[4], but grease rules come mostly from your plumbing code and utility, so ask them directly. If a supplier recall ever leaves you discarding large amounts of food, dispose of it as solid waste rather than through the drains; see what to do when a supplier recalls food.
Frequently asked questions
How often should a restaurant grease trap be cleaned?
As often as your local utility requires, and more often if measurements show grease and solids building quickly. EPA notes that frequency depends on how much FOG you produce and on your kitchen practices[1].
Who regulates restaurant grease traps?
Mainly your local sewer utility, under its pretreatment or FOG ordinance, with plumbing codes setting design. The health code requires grease traps to be accessible for cleaning[2].
Can I clean the grease trap myself?
Some utilities allow staff to clean small under-sink traps; many require licensed haulers for interceptors. Ask your utility, and keep a log either way.
Can I pour used fryer oil down the drain?
No. Collect it in a covered container for a recycling or rendering service, and keep the receipts.
References
US Environmental Protection Agency (2012). Controlling Fats, Oils, and Grease Discharges from Food Service Establishments (EPA-833-F-12-003) (opens in a new tab) ↑
US Food and Drug Administration (2022). FDA Food Code 2022 (opens in a new tab) ↑
NYC Department of Health and Mental Hygiene (2025). Rules of the City of New York, Title 24, Chapter 23: Food Service Establishment Inspection Procedures (opens in a new tab) ↑
US Food and Drug Administration (2026). FDA Food Code (opens in a new tab) ↑